Hello, community,
I modified the original fans of my x3250 M5 system because they were noisy.
As a replacement, I installed Noctua NF-A4x20 PWM these fans have a different specification.
Rotational speed Max 5000 RPM
Rotational speed min 1200 RPM
I would like to change the values in IMM, because at the moment I have this to set.
ipmitool
Fan 1 Tach | 5040.000 | RPM | ok | na | 3500.000 | na | na | na | na
Fan 2 Tach | 5390.000 | RPM | ok | na | 3500.000 | na | na | na | na
Fan 3 Tach | 5250.000 | RPM | ok | na | 3500.000 | na | na | na | na
Fan 4 Tach | 5460.000 | RPM | ok | na | 3500.000 | na | na | na | na
Fan 5 Tach | 5320.000 | RPM | ok | na | 3500.000 | na | na | na | na
ipmiutil
_ID_ SDR_Type_xx ET Own Typ S_Num Sens_Description Hex & Interp Reading
000a SDR Full 01 01 20 a 04 snum 40 Fan 1 Tach = 49 OK 5110.00 RPM
000b SDR Full 01 01 20 a 04 snum 41 Fan 2 Tach = 21 Crit-lo 2310.00 RPM
000c SDR Full 01 01 20 a 04 snum 42 Fan 3 Tach = 48 OK 5040.00 RPM
000d SDR Full 01 01 20 a 04 snum 43 Fan 4 Tach = 41 OK 4550.00 RPM
000e SDR Full 01 01 20 a 04 snum 44 Fan 5 Tach = 35 OK 3710.00 RPM
I would like to modify in order to have these parameters.
Fan 1 Tach | 5040.000 | RPM | ok | 1100.000 | 1200.000 | 1300.000 | 4800.000 | 4900.000 | 5000.000
The speed of the fans goes up and down all the time, I have my event log that is saturated.
1f0 | 11/15/2019 | 17:37:59 | Fan #0x41 | Lower Critical going low | Asserted
1f1 | 11/15/2019 | 17:37:59 | Fan #0x43 | Lower Critical going low | Asserted
1f2 | 11/15/2019 | 17:38:01 | Fan #0x40 | Lower Critical going low | Asserted
1f3 | 11/15/2019 | 17:38:01 | Fan #0x42 | Lower Critical going low | Asserted
1f4 | 11/15/2019 | 17:38:02 | Fan #0x44 | Lower Critical going low | Asserted
1f5 | 11/15/2019 | 17:38:03 | Fan #0x41 | Lower Critical going low | Deasserted
1f6 | 11/15/2019 | 17:38:03 | Fan #0x43 | Lower Critical going low | Deasserted
1f7 | 11/15/2019 | 17:38:05 | Fan #0x42 | Lower Critical going low | Deasserted
1f8 | 11/15/2019 | 17:38:09 | Fan #0x40 | Lower Critical going low | Deasserted
1f9 | 11/15/2019 | 17:38:10 | Fan #0x44 | Lower Critical going low | Deasserted
1ff | 11/15/2019 | 17:38:26 | Event Logging Disabled #0xf6 | Log full | Asserted
I have tested several commands, but nothing works.
ipmiutil sensor -N 12.11.01.11 -U USERID -P PASSW0RD -n 40 -l 1100 1200 1300 -h 4800 4900 5000
ipmiutil sensor version 3.13
sensor_num = 0x40
-- BMC version 7.20, IPMI version 2.0
_ID_ SDR_Type_xx ET Own Typ S_Num Sens_Description Hex & Interp Reading
000a SDR Full 01 01 20 a 04 snum 40 Fan 1 Tach = 4a OK 5180.00 RPM
Setting SDR 000a sensor 40 to lo=10 hi=45
GetThreshold[40]: 40 02 00 32 00 00 00 00
SetThreshold[40]: 40 02 10 0f 0e 45 46 47
SetSensorThreshold[40] to lo=10(1100.000) hi=45(4800.000), ret = 204
ipmiutil sensor, Invalid data field in request
ipmitool -I lanplus -H 12.11.01.11 -U USERID -P PASSW0RD sensor thresh "Fan 1 Tach" lower 1100 1200 1300
Locating sensor record 'Fan 1 Tach'...
Setting sensor "Fan 1 Tach" Lower Non-Recoverable threshold to 1100.000
Error setting threshold: Invalid data field in request
Setting sensor "Fan 1 Tach" Lower Critical threshold to 1200.000
Error setting threshold: Invalid data field in request
Setting sensor "Fan 1 Tach" Lower Non-Critical threshold to 1300.000
Error setting threshold: Invalid data field in request
ipmitool -I lanplus -H 12.11.01.11 -U USERID -P PASSW0RD sensor thresh "Fan 1 Tach" upper 4800 4900 5000
Locating sensor record 'Fan 1 Tach'...
Setting sensor "Fan 1 Tach" Upper Non-Critical threshold to 4800.000
Error setting threshold: Invalid data field in request
Setting sensor "Fan 1 Tach" Upper Critical threshold to 4900.000
Error setting threshold: Invalid data field in request
Setting sensor "Fan 1 Tach" Upper Non-Recoverable threshold to 5000.000
Error setting threshold: Invalid data field in request
Do you have any idea?? Maybe one of you has already encountered this problem?
Thank you.